Ideal for all pH testing, water
purification applications, wastewater regulation, aquaculture, hydroponics,
colloidal silver, labs & scientific testing, pools & spas, ecology
testing, boilers & cooling towers, water treatment, wine, coffee,
agriculture and more.
FEATURES
- Measures pH and Temperature
- Auto-ranging three point calibration with digital fine
tuning
- Includes storage solution
in a sponge embedded in a clear cap
- Waterproof housing (IP-67 rating)
- Simultaneous temperature display
- Measurement Range: 0-14 pH
- Digital automatic calibration (one point), with digital
fine tuning
- Automatic Temperature Compensation (ATC)
- Auto-off function, data-hold function and low-battery
indicator
- Display: large and easy-to-read LCD screen includes
simultaneous temperature reading
- Replaceable Sensor (model SP-P2)
- Factory Calibrated: The PH-200 meter is three-point checked and factory
calibrated to pH 7.0. It can be re-calibrated to any point in its
range with digital calibration using the push buttons.
- Includes a cap, batteries, lanyard, and pH 7.0
buffer
SPECIFICATIONS
pH Range: 0 - 14
Temperature Range: 0-80 C; 32-176 F
Resolution: 0.01 pH; Temperature resolution is 0.1 C/F
Accuracy: +/- 0.02 pH; Temperature accuracy is +/-2%
Calibration: Digital automatic calibration (one point) with digital fine
tuning
Minimum EC/TDS: 5 uS/10 ppm
Electrode: Replaceable glass sensor and reference tube electrodes
Housing: IP-67 Waterproof (submersible; floats)
Power source: 3 x 1.5V button cell batteries (LR44 or equivalent;
included)
Dimensions: 18.5 x 3.4 x 3.4 cm (7.3 x 1.3 x 1.3 inches)
Weight: 96.4 g (3.4 oz)
FAQs
The sponge in my cap is
dry. Is this okay?
Yes. During shipping, it is possible for the solution to leak or dry.
This will not damage your meter, and it's perfectly fine, since the cap
was on and it was in the box. Prior to use, pour a small amount of
the electrode storage
solution (from the Mylar
packet) into the sponge so that it's moist. Put the cap back on and allow
the sensor to soak for 15 minutes standing upright. Additional storage
solution is available for purchase. (NOTE: The sponge is simply for
retaining the storage solution so that it doesn't spill. It should be kept
in the cap.)
How often do I need to
calibrate?
All pH meters should be calibrated anywhere from before every use to at least
once a month. The frequency of calibration depends on usage and
application, but you should calibrate at least once per month for proper
results and a longer lifespan of your meter. A free packet of pH 7.0
buffer is included with the meter. Additional pH buffers for calibration are available for purchase. Please
consult the user's guide for calibration instructions.
I use my meter for
hydroponics. Does it need any special care?
Yes. Nutrients in a hydroponics reservoir will quickly adhere to the
sensor and throw off readings. It is very important to rinse the sensor in
distilled water after each use. Otherwise, you'll just be measuring the
nutrients that are already on the sensor.
Can I use the PH-200 for
testing distilled, DI or RO water?
No. The meter is not designed for pure or very low TDS water. The
water needs at least 10 ppm of TDS (S of EC) to pick up a
reading.
|